Specifications
- Integrated amplifier
- Output signal: 4…20mA/ CANopen/ 0…10 V DC
- Measurement range: 0...1 kN to 0...500 kN
- Protection rating: IP67 acc. to DIN EN 60529
- Rated temperature BT,nom: -20...+80°C
- Operating temperature BT, G: -40...+80°C (F2301 and F23C1 with UL), -30...+80°C (F23S1)
- Storage temperature BT, S :-40...+85°C
- Electrical connection: M12, CANopen
- Material of sensor body: corrosion-proof stainless steel
- Vibration resistance: 20 g, 100 h, 50...150 Hz (acc. to DIN EN 60068-2-6)
- Shock resistance: In accordance with DIN EN 60068-2-27
- Immunity: In accordance with DIN EN 61326-1/DIN EN 61326-2-3, EMC-strengthened version
- Approved for use in explosive atmospheres (certificates: ATEX acc. to EN 60079/ IECEx acc. to EN 60079/ UL)
- Redundant versions available
- Thin film technology