Specifications
- Measurement technology: hermetically welded thin-film measurement cells
- Measurement range: 0…60 bars to 0...1,000 bars
- Configuration options:
7 standard measurement ranges (intermediate ranges possible)
3 process connections
CANopen® or SAE J1939 protocol
CAN interface configuration
Y connector - Overload protection:
Measurement ranges ≤ 600 bars: 200%
Measurement ranges > 600 bars: 150% - Temperature of medium: -40°C to +125°C
- Shock-/vibration-resistance: 500g / 20g
- Electromagnetic compatibility: up to 100 V/m
- Protection class: IP6K9K
- Parts in contact with measured medium: CrNi steel
- Housing: CrNi steel
- Electrical connection: M12x1, five-pole
- Maximum systematic measurement errors:
Standard: ≤ ±1 % FS
Optional: ≤ ±0.5 % FS
Accuracy of pressure sensors