Specifications
- Measurement technology: hermetically welded thin-film measurement cells
- Measurement range: 0…6 bars to 0...600 bars
- Configuration options:
12 standard measurement ranges (intermediate ranges possible)
5 analog output signals
6 electrical connections
6 process connections
Signal clamping
Diagnostic functions - Overload protection: 200%
- Temperature of medium: -40°C to +125°C
- Shock-/vibration-resistance: 500g / 20g
- Electromagnetic compatibility: up to 100 V/m
- Protection class: IP67 up to IP6K9K
- Parts in contact with measured medium: CrNi steel
- Housing: fiberglass-reinforced plastic (PBT) with metallic shield
- Maximum systematic measurement errors:
Measurement ranges ≥ 40 bars: ±1% F.S.
Measurement ranges < 40 bars: ±2% F.S.
Accuracy of pressure sensors