WIKA Mobile Control GmbH & Co. KG

fSENS MA / F53x8

Load pins for any range of forces

Flexible, configurable load pins for your mobile machine

The robust fSENS MA load pins can be configured in standard and customized versions. Certified versions provide even greater safety for your mobile machines while maximizing their availability. 

Product Description

You need load pins for a particular force range?

Our robust fSENS load pins are used to directly measure dynamic or static tensile or compressive forces. They can be configured in standard or customized versions to meet the needs of virtually any application. Our load pins are highly suited for use in harsh and demanding environmental conditions and are compactly designed for space-saving installation.

Overview

  • Measurement of static and dynamic forces
  • Flexibly designable for virtually any installation situation and application
  • Produced with the geometries you specify
  • Robust design
  • Excellent long-term stability and consistent accuracy
  • Strain gauges and thin film technology
  • Integrated safety
  • Also available in redundant opposing versions

Product Types

 

fSENS MA
Configurable load pins for any range of forces

F53x8

Heavy-duty model incorporating thin-film technology for measuring large forces of more than 10 kN

Specifications

  • Integrated amplifier
  • Output signal: 4…20mA/ CANopen/ 0…10 V DC
  • Supply voltage: 10…30 V DC
  • Measurement range: 0.5...1,000t
  • Protection rating: IP66/67 acc. to DIN EN 60529 (optionally IP69k and IP68)
  • Temperature range: -40°C to +80°C
  • Electrical connection: M12, Cannon, cable connector (cable gland)
  • Material of sensor body: corrosion-proof stainless steel
  • High resistance to vibration acc. to DIN 60068
  • Electromagnetic compatibility acc. to DIN 61326
  • Strain gauges and thin film technology
  • No zero-point drift, i.e. no recalibration required
  • High overload resistance: >300% Fnom (standard)
  • Approved for use in explosive atmospheres (certificates: ATEX acc. to EN 60079/ IECEx acc. to EN 60079/ UL)
  • DNV GL tested
  • Redundant versions available
  • trueSafety-certified acc. to EN 13849 (PL d) and SIL 2 as per IEC 61508

 

More information about our trueSafety certification